Availability: | |
---|---|
Quantity: | |
Key Features:
♦ GS Series AC/Solar charging Off grid Hybrid Inverter.
♦ LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design.
♦ Built-in 40A/60A optional MPPT solar charger controller.
♦ LCD shows the solar capacity.
♦ 5 stages adjustable AC charging current. AC charging also can be closed.
♦ AC/DC priority modes can be set.
♦ Generator restart signal. (Dry contact)
♦ 3 times peak power. Strong loading capacity.
♦ Overload, output short-circuit protection.
Spefication:
Model Parameters | GS8KW | GS10KW | GS12KW | |
AC Input | Nominal Power | 8KW | 10KW | 12KW |
Input Voltage Waveform | sinusoidal(utility or generator) | |||
Nominal input Voltage | 230VAC | |||
Low Line Disconnect | 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | |||
Low Line Re-connect | 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | |||
High Line Disconnect | 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | |||
Max AC input Voltage | 230V for Max270V | |||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | |||
AC output | Output Voltage Waveform | Sine wave | ||
Power Factor | 0.9~1.0 | |||
Nominal Output Voltage(V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | |||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | |||
Solar charger | Rated Charge Current | 60A | ||
PV Input Voltage range | 60-110VDC for 48V | |||
Max.PV open circuit array voltage | 48V for 110Vdc | |||
Charger mode | MPPT | |||
PV Low Voltage Re-connect | PV≥Bat.V+3V | |||
PV Low Voltage Disconnect | PV<=Bat.V | |||
Efficiency | ≥97% | |||
AC Charger | Nominal Charger Current | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | ||
Over charge Protection | Bat.V≥31.0VDC for 24V battery, Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | |||
Charger | Nominal Charger Current | 20A/35A/50A/70A/90A(According to the inverter model) adjustable 5 stages charging current | ||
Over charge Protection | Bat.V≥15.5VDC/31.0VDC/62.0VDC, beeps 0.5s every 1s & fault after 60s | |||
Efficiency | Efficiency(Battery Mode) | ≥87% | ||
Efficiency (Line Mode) | >98% | |||
Battery Voltage | Nominal DC input Voltage | 48VDC | ||
Low Battery Alarm | 42VDC±1.2VDC for 48VDC | |||
Low DC input shut & down | 40VDC±1.2VDC for 48VDC | |||
High DC input Alarm & Fault | 64VDC±1.2VDC for 48VDC | |||
Transfer Time | AC tO DC | 20ms(max) | ||
DC tO AC | 15ms(max) | |||
System Parameter | Over-Load Protection | 110%the output,load>150%,beeps 0.5s every 1s,and Fault after 20s | ||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||
Surge Rating(10s) | 1:3(VA) | |||
Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | |||
Protections | Low battery, over charging, over load, over temp | |||
Indicators | LED+LCD Display | |||
General Specifications | Operating Temperature Range | 0ºC~40ºC | ||
Storage Temperature | -15ºC~60ºC | |||
Operation humidity | 5% to 95%(non-condensing) | |||
Audible Noise | 60dB max | |||
cooling | Forced air, variable speed fan | |||
Dimension(L*W*H) | 627*416*204mm | |||
Net Weight(kg) | 52.5 | 58.5 | 66.5 |
IFIND HYBRID INVERTER products charger combines the functions of an inverter, solar charger, and battery charger, providing uninterrupted power supply support in a portable size.
With dual PV input and dual MPPT voltage tracking, this hybrid inverter offers maximum efficiency and flexibility. It features different working modes, including purple photovoltaic mode, red battery mode, and blue utility mode, allowing you to adapt to various power sources and optimize energy usage.
Key Features:
♦ GS Series AC/Solar charging Off grid Hybrid Inverter.
♦ LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design.
♦ Built-in 40A/60A optional MPPT solar charger controller.
♦ LCD shows the solar capacity.
♦ 5 stages adjustable AC charging current. AC charging also can be closed.
♦ AC/DC priority modes can be set.
♦ Generator restart signal. (Dry contact)
♦ 3 times peak power. Strong loading capacity.
♦ Overload, output short-circuit protection.
Spefication:
Model Parameters | GS8KW | GS10KW | GS12KW | |
AC Input | Nominal Power | 8KW | 10KW | 12KW |
Input Voltage Waveform | sinusoidal(utility or generator) | |||
Nominal input Voltage | 230VAC | |||
Low Line Disconnect | 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | |||
Low Line Re-connect | 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | |||
High Line Disconnect | 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | |||
Max AC input Voltage | 230V for Max270V | |||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | |||
AC output | Output Voltage Waveform | Sine wave | ||
Power Factor | 0.9~1.0 | |||
Nominal Output Voltage(V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | |||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | |||
Solar charger | Rated Charge Current | 60A | ||
PV Input Voltage range | 60-110VDC for 48V | |||
Max.PV open circuit array voltage | 48V for 110Vdc | |||
Charger mode | MPPT | |||
PV Low Voltage Re-connect | PV≥Bat.V+3V | |||
PV Low Voltage Disconnect | PV<=Bat.V | |||
Efficiency | ≥97% | |||
AC Charger | Nominal Charger Current | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | ||
Over charge Protection | Bat.V≥31.0VDC for 24V battery, Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | |||
Charger | Nominal Charger Current | 20A/35A/50A/70A/90A(According to the inverter model) adjustable 5 stages charging current | ||
Over charge Protection | Bat.V≥15.5VDC/31.0VDC/62.0VDC, beeps 0.5s every 1s & fault after 60s | |||
Efficiency | Efficiency(Battery Mode) | ≥87% | ||
Efficiency (Line Mode) | >98% | |||
Battery Voltage | Nominal DC input Voltage | 48VDC | ||
Low Battery Alarm | 42VDC±1.2VDC for 48VDC | |||
Low DC input shut & down | 40VDC±1.2VDC for 48VDC | |||
High DC input Alarm & Fault | 64VDC±1.2VDC for 48VDC | |||
Transfer Time | AC tO DC | 20ms(max) | ||
DC tO AC | 15ms(max) | |||
System Parameter | Over-Load Protection | 110%the output,load>150%,beeps 0.5s every 1s,and Fault after 20s | ||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||
Surge Rating(10s) | 1:3(VA) | |||
Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | |||
Protections | Low battery, over charging, over load, over temp | |||
Indicators | LED+LCD Display | |||
General Specifications | Operating Temperature Range | 0ºC~40ºC | ||
Storage Temperature | -15ºC~60ºC | |||
Operation humidity | 5% to 95%(non-condensing) | |||
Audible Noise | 60dB max | |||
cooling | Forced air, variable speed fan | |||
Dimension(L*W*H) | 627*416*204mm | |||
Net Weight(kg) | 52.5 | 58.5 | 66.5 |
IFIND HYBRID INVERTER products charger combines the functions of an inverter, solar charger, and battery charger, providing uninterrupted power supply support in a portable size.
With dual PV input and dual MPPT voltage tracking, this hybrid inverter offers maximum efficiency and flexibility. It features different working modes, including purple photovoltaic mode, red battery mode, and blue utility mode, allowing you to adapt to various power sources and optimize energy usage.